{"title":"Agility","description":"","products":[{"product_id":"agility-soft-starter-132kw-242a-tc10-200-600vac","title":"AGILITY Soft Starter 132kW, 242A TC10 200-600Vac","description":"\u003cdiv\u003e\n\u003cp itemprop=\"description\"\u003eMotortronics Agility Series Soft Starter suitable for starting standard three phase induction motors to 132kW (200HP) at 242A subject to application.\u003c\/p\u003e\n\u003cp\u003eRated to suit motors and Trip Class Ratings:-\u003cbr\u003e132kW, 242A at 400V - Trip Class 10.\u003cbr\u003e110kW, 195A at 400V - Trip Class 20.\u003cbr\u003e90kW, 160A at 400V - Trip Class 30. See trip class guide below.\u003cbr\u003eCan also be used on 230V 3phase and 500V supplies, see manual for details.\u003c\/p\u003e\n\u003cp\u003eThe Agility frame 3 soft starters have an integral fan.\u003c\/p\u003e\n\u003cp\u003eMain Circuit IP00 (IP20 with optional finger guard, see linked products below). Control Circuit IP20.\u003c\/p\u003e\n\u003cp\u003eFrame 3 Dimesnsions: 490mm high x 205mm wide x 332mm deep. \u003cbr\u003eWeight: 15kg.\u003c\/p\u003e\n\u003cp\u003eFeatures include:\u003cbr\u003eIntegral OLED Display for fast programming.\u003cbr\u003eInternal bypass.\u003cbr\u003e2 x Digital Inputs, 1 x Run Relay, 1 x Fault Relay. \u003cbr\u003eUSB terminal for firmware upgrades and data logging.\u003cbr\u003eRJ45 socket for Modbus RTU communications.\u003c\/p\u003e\n\u003cp\u003eInput Voltage: 200Vac to 600Vac, at 50\/60Hz +\/- 10%\u003cbr\u003eSupply fuse rating: 800A semiconductor type aR - see linked products below.\u003cbr\u003eRequires external power supply (not included, see linked products below) or compatible 24V 2A DC supply for operation\u003c\/p\u003e\n\u003cp\u003eCubicle mount.\u003cbr\u003eVentilation space above and below: 100mm\u003cbr\u003eVentilation space at sides: 40mm\u003cbr\u003eVentilation space in front: 25mm\u003cbr\u003eMounting via 4 bolts at rear on 283mm x 75mm centres.\u003cbr\u003eOperating Temp: -20°C to 40°C. Above 40°C derate linearly by 2% per °C to a maximum of 60°C\u003cbr\u003eHeat loss: 90W.\u003c\/p\u003e\n\u003cp\u003eManufacturer part number is VMX-AGY-301-6-01. Identical to previous part  AGY-301-6-01 except for branding (Fairford became Motortronics UK in 2019).\u003cbr\u003e\u003cbr\u003eDownload the Motortronics Agility Manuals from the links below:-\u003c\/p\u003e\n\u003c\/div\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59018882777169,"sku":"AGY-301-6-01","price":5624.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Motortronics_AGY.jpg?v=1777721840"},{"product_id":"agility-external-110v-230v-power-supply-also-converts-digital-inputs-outputs-to-110v-230v","title":"AGILITY External 110V-230V Power Supply Also converts digital inputs\/outputs to 110V\/230V","description":"\u003cp itemprop=\"description\"\u003eFairford Electronics 110V to 230V external power supply for Agility Soft Starters. For use with all current sizes of Agility. \u003c\/p\u003e\n\u003cp\u003eOne VMX-AGY-021 per Agility soft starter.\u003c\/p\u003e\n\u003cp\u003eAllows for mains control operation. Also allows mains voltage control of D1\/D2.\u003c\/p\u003e\n\u003cp\u003ePart No: VMX-AGY-021 (replaces AGY-020, AGY-21)\u003c\/p\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59023475408977,"sku":"AGY-021","price":599.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Motortronics-AGY-021.jpg?v=1777724320"},{"product_id":"agility-remote-keypad","title":"AGILITY Remote Keypad","description":"","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060499382353,"sku":"AGY-012","price":562.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Image6.jpg?v=1772583929"},{"product_id":"agility-external-fan-for-size-1-increase-starts-up-to-40-per-hour","title":"AGILITY External Fan for Size 1 Increase starts up to 40 per hour","description":"\u003cdiv\u003e\n\u003cp itemprop=\"description\"\u003eMotortronics Fan Option for Agility Frame 1 Soft Starters AGY101 - AGY-113\u003c\/p\u003e\n\u003cp\u003eNecessary to increase the number of starts from 5 start\/ stops per hour to 40.\u003c\/p\u003e\n\u003cp\u003ePart No: VMX-AGY-030  (was AGY-030)\u003c\/p\u003e\n\u003cp\u003eInstructions on how to fit the fan are in the manual below:-\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul class=\"linkedfiles\"\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-MAN-AGY-004-V02.pdf?v=1770350149\" target=\"_blank\" rel=\"noopener\"\u003eMAN AGY-004\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060499447889,"sku":"AGY-030","price":224.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/motortronics-AGY-031.jpg?v=1777725816"},{"product_id":"agility-external-fan-for-size-2-increase-starts-up-to-40-per-hour","title":"AGILITY External Fan for Size 2 Increase starts up to 40 per hour","description":"\u003cp itemprop=\"description\"\u003eMotortronics Fan Option for Agility Frame 2 Soft Starters AGY-201 - AGY-209\u003c\/p\u003e\n\u003cp\u003eAllows the user to increase the number of starts per hour to 10 up to 40, depending on the rating.\u003c\/p\u003e\n\u003cp\u003eAGY-201 to AGY-203: 40 start\/ stops per hour.\u003c\/p\u003e\n\u003cp\u003eAGY-205: 30 start\/ stops per hour.\u003c\/p\u003e\n\u003cp\u003eAGY-207: 20 start\/ stops per hour.\u003c\/p\u003e\n\u003cp\u003eAGY-209: 10 start\/ stops per hour.\u003c\/p\u003e\n\u003cp\u003ePart No: VMX-AGY-031 (was AGY-031)\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eInstructions on how to fit the fan are in the manual below:-\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul class=\"linkedfiles\"\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-MAN-AGY-004-V02.pdf?v=1770350149\" rel=\"noopener\" target=\"_blank\"\u003eMAN AGY-004\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060499480657,"sku":"AGY-031","price":227.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/motortronics-AGY-031.jpg?v=1777725816"},{"product_id":"i-o-expansion-module","title":"AGILITY I\/O Expansion Module","description":"\u003cp class=\"p1\"\u003eThe expansion module (VMX-AGY-071) can be used to provide extra I\/O to our current range of\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eVMX-agility\u003cspan class=\"s1\"\u003eTM \u003c\/span\u003emotor controllers. The module is self-powered, therefore there is no need for an\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eadditional supply to power it.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eThe expansion module provides the following additional I\/O:\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e•\u003cspan class=\"s2\"\u003e \u003c\/span\u003e2 x Digital Inputs.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e•\u003cspan class=\"s2\"\u003e \u003c\/span\u003e2 x Digital Outputs.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e•\u003cspan class=\"s2\"\u003e \u003c\/span\u003e1 x PTC Thermistor Input.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eInstallation\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eThe expansion module (VMX-AGY-071) is DIN rail mounted, thus allowing for easy installation.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eThe ribbon cable that exits out from the top of the expansion module connects into adaptor module.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p1\"\u003edownload installation manual\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060499513425,"sku":"AGY-071","price":639.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/motortronics-AGY-071.jpg?v=1777725531"},{"product_id":"agility-soft-starter-7-5kw-17a-tc10-200-600vac","title":"AGILITY Soft Starter - 7.5kW, 17A TC10 200-600Vac","description":"\u003cp itemprop=\"description\"\u003eMotortronics Agility soft starter for a 3 phase motor up to 7.5kW (10HP) at 17A, 400V subject to application.\u003c\/p\u003e\n\u003cp\u003eRated to suit motors and Trip Class Ratings:-\u003cbr\u003e7.5kW, 17A at 400V - Trip Class 10, 20, 30. See trip class guide below.\u003cbr\u003eCan also be used on 230V 3 phase and 500V supplies, see the manual for details.\u003c\/p\u003e\n\u003cp\u003eUp to 5 starts per hour as standard, Up to 40 starts per hour if optional fan is fitted, see linked products below.\u003c\/p\u003e\n\u003cp\u003eMain Circuit IP00 (IP20 with optional finger guard, see linked products below). Control Circuit IP20.\u003c\/p\u003e\n\u003cp\u003eFrame 1: 165mm high x 108mm wide x 148mm deep. \u003cbr\u003eWeight: 1.97kg.\u003c\/p\u003e\n\u003cp\u003eFeatures include:\u003cbr\u003eIntegrated Keypad with Display.\u003cbr\u003eInternal bypass.\u003cbr\u003e2 x Digital Inputs,1 x Run Relay, 1 x Fault Relay. \u003cbr\u003eUSB terminal for firmware upgrades and data logging.\u003cbr\u003eRJ45 Socket for Modbus RTU communications.\u003c\/p\u003e\n\u003cp\u003eInput Voltage: 200Vac to 600Vac, at 50\/60Hz +\/- 10%\u003cbr\u003eSupply fuse rating: 160A, semiconductor aR type - see linked products below.\u003cbr\u003eRequires external power supply (not included, see linked products below) or compatible 24V, 12VA (0.5A) DC supply for operation.\u003c\/p\u003e\n\u003cp\u003eCubicle mount.\u003cbr\u003eVentilation space above and below: 75mm\u003cbr\u003eVentilation space at sides: 25mm\u003cbr\u003eVentilation space in front: 25mm\u003cbr\u003eMounting via 4 bolts at rear on 165mm x 90mm centres.\u003cbr\u003eOperating Temp: -20°C to 40°C. Above 40°C derate linearly by 2% per °C to a maximum of 60°C\u003cbr\u003eHeat loss: 9W.\u003c\/p\u003e\n\u003cp\u003eManufacturer part number is VMX- AGY-101-6-01. Identical to previous part AGY-101-6-01 except for branding (Fairford became Motortronics UK in 2019).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eDownload the Motortronics Agility Manuals from the links below:-\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul class=\"linkedfiles\"\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-015-Manual.pdf?v=1774223072\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-Quick-Start-Guide.pdf?v=1774223032\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Quick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-Soft-Starter-Trip-Class-Guide.pdf?v=1769575444\" rel=\"noopener\" target=\"_blank\"\u003eSoft Starter Trip Class Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060499546193,"sku":"AGY-101-6-01","price":1414.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Motortronics_AGY.jpg?v=1777721840"},{"product_id":"agility-soft-starter-11kw-22a-tc10-200-600vac","title":"AGILITY Soft Starter - 11kW, 22A TC10 200-600Vac","description":"\u003cp itemprop=\"description\"\u003eMotortronics Agility Series Soft Starter suitable for starting standard three phase induction motors to 11kW (15HP) at 22A subject to application.\u003c\/p\u003e\n\u003cp\u003eRated to suit motors and Trip Class Ratings:-\u003cbr\u003e11kW, 22A at 400V - Trip Class 10.\u003cbr\u003e7.5kW, 17A at 400V - Trip Class 20, 30. See trip class guide below.\u003cbr\u003eCan also be used on 230V 3 phase and 500V supplies, see manual for details.\u003c\/p\u003e\n\u003cp\u003eUp to 5 starts per hour as standard, Up to 40 starts per hour if optional fan is fitted, see linked [roducts below.\u003c\/p\u003e\n\u003cp\u003eMain Circuit IP00 (IP20 with optional finger guard, see linked products below). Control Circuit IP20.\u003c\/p\u003e\n\u003cp\u003eFrame 1: 165mm high x 108mm wide x 148mm deep. \u003cbr\u003eWeight: 1.97kg.\u003c\/p\u003e\n\u003cp\u003eFeatures include:\u003cbr\u003eIntegrated Keypad with Display.\u003cbr\u003eInternal Bypass.\u003cbr\u003e2 x Digital Inputs, 1 x Run Relay, 1 x Fault Relay. \u003cbr\u003eUSB terminal for firmware upgrades and data logging.\u003cbr\u003eRJ45 Socket for Modbus RTU communications.\u003c\/p\u003e\n\u003cp\u003eInput Voltage: 200Vac to 600Vac, at 50\/60Hz +\/- 10%\u003cbr\u003eSupply fuse rating: 160A, semiconductor aR type - see linked products below.\u003cbr\u003eRequires external power supply (not included, see linked products below) or compatible 12VA , 24V(0.5A) DC supply for operation.\u003c\/p\u003e\n\u003cp\u003eCubicle mount.\u003cbr\u003eVentilation space above and below: 75mm\u003cbr\u003eVentilation space at sides: 25mm\u003cbr\u003eVentilation space in front: 25mm\u003cbr\u003eMounting via 4 bolts at rear on 165mm x 90mm centres.\u003cbr\u003eOperating Temp: -20°C to 40°C. Above 40°C derate linearly by 2% per °C to a maximum of 60°C\u003cbr\u003eHeat loss: 12W.\u003c\/p\u003e\n\u003cp\u003eManufacturer part number is VMX-AGY-103-6-01.  Identical to previous part  AGY-103-6-01 (Fairford became Motortronics UK in 2019).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eDownload the Motortronics Agility Manuals from the links below:-\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul class=\"linkedfiles\"\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-015-Manual.pdf?v=1774223072\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-Quick-Start-Guide.pdf?v=1774223032\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Quick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-Soft-Starter-Trip-Class-Guide.pdf?v=1769575444\" rel=\"noopener\" target=\"_blank\"\u003eSoft Starter Trip Class Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060499578961,"sku":"AGY-103-6-01","price":1476.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Motortronics_AGY.jpg?v=1777721840"},{"product_id":"agility-soft-starter-15kw-29a-tc10-200-600vac","title":"AGILITY Soft Starter - 15kW, 29A TC10 200-600Vac","description":"\u003cp itemprop=\"description\"\u003eMotortronics Agility Series Soft Starter suitable for starting standard three phase induction motors to 15kW (20HP) at 29A subject to application.\u003c\/p\u003e\n\u003cp\u003eRated to suit motors and Trip Class Ratings:-\u003cbr\u003e15kW, 29A at 400V - Trip Class 10.\u003cbr\u003e11kW, 22A at 400V - Trip Class 20.\u003cbr\u003e7.5kW, 17A at 400V - Trip Class 30. See trip class guide below.\u003cbr\u003eCan also be used on 230V 3 phase and 500V supplies, see manual for details.\u003c\/p\u003e\n\u003cp\u003eUp to 5 starts per hour as standard, up to 40 starts per hour if optional fan is fitted - see linked products below.\u003c\/p\u003e\n\u003cp\u003eMain Circuit IP00 (IP20 with optional finger guard, see linked products below). Control Circuit IP20.\u003c\/p\u003e\n\u003cp\u003eFrame 1 Dimensions: 165mm high x108mm wide x148mm deep. \u003cbr\u003eWeight: 1.97kg.\u003c\/p\u003e\n\u003cp\u003eFeatures include:\u003cbr\u003eIntegrated Keypad with Display.\u003cbr\u003eInternal bypass.\u003cbr\u003e2 x Digital Inputs, 1 x Run Relay, 1 x Fault Relay.\u003cbr\u003eUSB terminal for firmware upgrades and data logging.\u003cbr\u003eRJ45 Socket for Modbus RTU communications.\u003c\/p\u003e\n\u003cp\u003eInput Voltage: 200Vac to 600Vac, at 50\/60Hz +\/- 10%\u003cbr\u003eSupply fuse rating: 200A semiconductor aR type - see linked products below.\u003cbr\u003eRequires external power supply (not included, see linked products below) or compatible 12VA24V (0.5A) DC supply for operation\u003c\/p\u003e\n\u003cp\u003eCubicle mount.\u003cbr\u003eVentilation space above and below: 75mm\u003cbr\u003eVentilation space at sides: 25mm (each side)\u003cbr\u003eVentilation space in front: 25mm\u003cbr\u003eMounting via 4 bolts at rear on 165mm x 90mm centres.\u003cbr\u003eOperating Temp: -20°C to 40°C. Above 40°C derate linearly by 2% per °C to a maximum of 60°C\u003cbr\u003eHeat loss: 14W.\u003c\/p\u003e\n\u003cp\u003eManufacturer part number is VMX-AGY-105-6-01. Identical to previous part AGY-105-6-01 except for branding (Fairford became Motortronics UK in 2019).\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eDownload the Motortronics Agility Manuals from the links below:-\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul class=\"linkedfiles\"\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-015-Manual.pdf?v=1774223072\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-Quick-Start-Guide.pdf?v=1774223032\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Quick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-Soft-Starter-Trip-Class-Guide.pdf?v=1769575444\" rel=\"noopener\" target=\"_blank\"\u003eSoft Starter Trip Class Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060499611729,"sku":"AGY-105-6-01","price":1547.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Motortronics_AGY.jpg?v=1777721840"},{"product_id":"agility-soft-starter-18-5kw-35a-tc10-200-600vac","title":"AGILITY Soft Starter - 18.5kW, 35A TC10 200-600Vac","description":"\u003cp itemprop=\"description\"\u003eMotortronics Agility Series Soft Starter suitable for starting standard three phase induction motors to 18.5kW (25HP) at 35A, 400V subject to application.\u003c\/p\u003e\n\u003cp\u003eRated to suit motors and Trip Class Ratings:-\u003cbr\u003e18.5kW, 35A - Trip Class 10.\u003cbr\u003e15kW, 29A at 400V - Trip Class 20.\u003cbr\u003e11kW, 22A at 400V - Trip Class 30. See trip class guide below.\u003cbr\u003eCan also be used on 230V 3 phase and 500V supplies. See manuals for details.\u003c\/p\u003e\n\u003cp\u003eUp to 5 starts per hour as standard, Up to 40 starts per hour if optional fan is fitted - see linked products below.\u003c\/p\u003e\n\u003cp\u003eMain Circuit IP00 (IP20 with optional finger guard, see linked products below). Control Circuit IP20.\u003c\/p\u003e\n\u003cp\u003eFrame 1 Dimensions:165mm high x108mm wide x 148mm deep. \u003cbr\u003eWeight: 1.97kg.\u003c\/p\u003e\n\u003cp\u003eFeatures include:\u003cbr\u003eIntegrated Display with Keypad.\u003cbr\u003eInternal bypass.\u003cbr\u003e2 x Digital Inputs,1 x Run Relay, 1 x Fault Relay. \u003cbr\u003eUSB terminal for firmware upgrades and data logging..\u003cbr\u003eRJ45 Socket for Modbus RTU communications.\u003c\/p\u003e\n\u003cp\u003eInput Voltage: 200Vac to 600Vac, at 50\/60Hz +\/- 10%\u003cbr\u003eSupply fuse rating: 200A semiconductor fuse aR type - see linked products below.\u003cbr\u003eRequires external power supply (not included, see linked products below) or compatible 24V 2A DC supply for operation\u003c\/p\u003e\n\u003cp\u003eCubicle mount.\u003cbr\u003eVentilation space above and below: 75mm\u003cbr\u003eVentilation space at sides: 25mm (each side)\u003cbr\u003eVentilation space in front: 25mm\u003cbr\u003eMounting via 4 bolts at rear on 165mm x 90mm centres.\u003cbr\u003eOperating Temp: -20°C to 40°C. Above 40°C derate linearly by 2% per °C to a maximum of 60°C\u003cbr\u003eHeat loss: 16W.\u003c\/p\u003e\n\u003cp\u003eManufacturer part number is VMX-AGY-107-6-01  idetical to  AGY-107-6-01 except for branding (Fairford became Motortronics UK in 2019).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eDownload the Motortronics Agility Manuals from the links below:-\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul class=\"linkedfiles\"\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-015-Manual.pdf?v=1774223072\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-Quick-Start-Guide.pdf?v=1774223032\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Quick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-Soft-Starter-Trip-Class-Guide.pdf?v=1769575444\" rel=\"noopener\" target=\"_blank\"\u003eSoft Starter Trip Class Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060499644497,"sku":"AGY-107-6-01","price":1705.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Motortronics_AGY.jpg?v=1777721840"},{"product_id":"agility-soft-starter-22kw-41a-tc10-200-600vac","title":"AGILITY Soft Starter - 22kW, 41A TC10 200-600Vac","description":"\u003cp itemprop=\"description\"\u003eMotortronics Agility Series Soft Starter suitable for starting standard three phase induction motors to 22kW (20HP) at 41A subject to application.\u003c\/p\u003e\n\u003cp\u003eRated to suit motors and Trip Class Ratings:-\u003cbr\u003e22kW, 41A at 400V - Trip Class 10.\u003cbr\u003e18.5kW, 35A at 400V - Trip Class 20.\u003cbr\u003e15kW, 29A at 400V - Trip Class 30. See trip class guide below.\u003c\/p\u003e\n\u003cp\u003eCan also be used on 230V 3 phase and 500V supplies. See manual for details.\u003c\/p\u003e\n\u003cp\u003eUp to 5 starts per hour as standard, Up to 40 starts per hour if optional fan is fitted - see linked products below.\u003c\/p\u003e\n\u003cp\u003eMain Circuit IP00 (IP20 with optional finger guard). Control Circuit IP20.\u003c\/p\u003e\n\u003cp\u003eFrame 1 Dimensions: 165mm high x 108mm wide x148mm deep. \u003cbr\u003eWeight: 1.97kg.\u003c\/p\u003e\n\u003cp\u003eFeatures include:\u003cbr\u003eKeypad with Integrated Display.\u003cbr\u003eInternal bypass.\u003cbr\u003e2 x Digital Inputs, 1 x Run Relay, 1 x Fault Relay. \u003cbr\u003eUSB terminal for firmware upgrades and data logging.\u003cbr\u003eModbus RTU Fieldbus communications port built in.\u003c\/p\u003e\n\u003cp\u003eInput Voltage: 200Vac to 600Vac, at 50\/60Hz +\/- 10%\u003cbr\u003eSupply fuse rating: 250A semiconductor fuse type aR - see linked products below.\u003cbr\u003eRequires external power supply (not included, see linked products below) or compatible 24V 2A DC supply for operation.\u003c\/p\u003e\n\u003cp\u003eCubicle mount.\u003cbr\u003eVentilation space above and below: 75mm\u003cbr\u003eVentilation space at sides: 25mm (each side)\u003cbr\u003eVentilation space in front: 25mm\u003cbr\u003eMounting via 4 bolts at rear on 165mm x 90mm centres.\u003cbr\u003eOperating Temp: -20°C to 40°C. Above 40°C derate linearly by 2% per °C to a maximum of 60°C\u003cbr\u003eHeat loss: 20W.\u003c\/p\u003e\n\u003cp\u003eManufacturer part number is VMX-AGY-109-6-01. Identical to AGY-109-6-01 except for branding (Fairford became Motortronics UK in 2019).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eDownload the Motortronics Agility Manuals from the links below:-\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul class=\"linkedfiles\"\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-015-Manual.pdf?v=1774223072\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-Quick-Start-Guide.pdf?v=1774223032\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Quick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-Soft-Starter-Trip-Class-Guide.pdf?v=1769575444\" rel=\"noopener\" target=\"_blank\"\u003eSoft Starter Trip Class Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060499677265,"sku":"AGY-109-6-01","price":2028.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Motortronics_AGY.jpg?v=1777721840"},{"product_id":"agility-soft-starter-30kw-55a-tc10-200-600vac","title":"AGILITY Soft Starter - 30kW, 55A TC10 200-600Vac","description":"\u003cp itemprop=\"description\"\u003eMotortronics Agility Series Soft Starter suitable for starting standard three phase induction motors to 30kW (40HP) at 55A subject to application.\u003c\/p\u003e\n\u003cp\u003eRated to suit motors and Trip Class Ratings:-\u003cbr\u003e30kW, 55A at 400V - Trip Class 10.\u003cbr\u003e22kW, 47A at 400V - Trip Class 20.\u003cbr\u003e18.5kW, 35A at 400V - Trip Class 30. See trip guide below. \u003c\/p\u003e\n\u003cp\u003eCan also be used on 230V 3 phase and 500V supplies. See manual for details.\u003c\/p\u003e\n\u003cp\u003eUp to 5 starts per hour as standard, Up to 40 starts per hour if optional fan is fitted - see linked products for details.\u003c\/p\u003e\n\u003cp\u003eMain Circuit IP00 (IP20 with optional finger guard, see linked products below). Control Circuit IP20.\u003c\/p\u003e\n\u003cp\u003eFrame 1 Dimensions: 165mm high x 108mm wide x 148mm deep. \u003cbr\u003eWeight: 1.97kg.\u003c\/p\u003e\n\u003cp\u003eFeatures include:\u003cbr\u003eIntegrated Keypad with Display.\u003cbr\u003eInternal bypass.\u003cbr\u003e2 x Digital Inputs, 1 x Run Relay, 1 x Fault Relay. \u003cbr\u003eUSB terminal for firmware upgrades and data logging.\u003cbr\u003eModbus RTU Fieldbus communications port built in.\u003c\/p\u003e\n\u003cp\u003eInput Voltage: 200Vac to 600Vac, at 50\/60Hz +\/- 10%\u003cbr\u003eSupply fuse rating 160A, semiconductor fuse aR type - see linked product below.\u003cbr\u003eRequires external power supply (not included, see linked products below) or compatible 24V 2A DC supply for operation.\u003c\/p\u003e\n\u003cp\u003eCubicle mount.\u003cbr\u003eVentilation space above and below: 75mm\u003cbr\u003eVentilation space at sides: 25mm (each side)\u003cbr\u003eVentilation space in front: 25mm\u003cbr\u003eMounting via 4 bolts at rear on 165mm x 90mm centres.\u003cbr\u003eOperating Temp: -20°C to 40°C. Above 40°C derate linearly by 2% per °C to a maximum of 60°C\u003cbr\u003eHeat loss: 25W.\u003c\/p\u003e\n\u003cp\u003eManufacturer part number is VMX-AGY-111-6-01. Identical to previous part AGY-111-6-01 except for branding (Fairford became Mototronics in 2019).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eDownload the Motortronics Agility Manuals from the links below:-\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul class=\"linkedfiles\"\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-015-Manual.pdf?v=1774223072\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-Quick-Start-Guide.pdf?v=1774223032\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Quick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-Soft-Starter-Trip-Class-Guide.pdf?v=1769575444\" rel=\"noopener\" target=\"_blank\"\u003eSoft Starter Trip Class Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060499710033,"sku":"AGY-111-6-01","price":2146.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Motortronics_AGY.jpg?v=1777721840"},{"product_id":"agility-soft-starter-37kw-66a-tc10-200-600vac","title":"AGILITY Soft Starter - 37kW, 66A TC10 200-600Vac","description":"\u003cp itemprop=\"description\"\u003eMotortronics Agility Series Soft Starter suitable for starting standard three phase induction motors to 37kW (50HP) at 66A subject to appplication.\u003c\/p\u003e\n\u003cp\u003eRated to suit motors and Trip Class Ratings:-\u003cbr\u003e37kW, 66A at 400V - Trip Class 10.\u003cbr\u003e30kW, 55A at 400V - Trip Class 20.\u003cbr\u003e22kW, 41A at 400V - Trip Class 30. See trip calss guide below.\u003c\/p\u003e\n\u003cp\u003eCan also be used on a 230V 3 phase and 500V supply. See manual for details.\u003c\/p\u003e\n\u003cp\u003eUp to 5 starts per hour as standard, Up to 40 starts per hour if optional fan is fitted - see linked products for details.\u003c\/p\u003e\n\u003cp\u003eMain Circuit IP00 (IP20 with optional finger guard, see linked products below). Control Circuit IP20.\u003c\/p\u003e\n\u003cp\u003eFrame 1 Dimensions: 165mm high x 108mm wide x 148mm deep. \u003cbr\u003eWeight: 1.97kg.\u003c\/p\u003e\n\u003cp\u003eFeatures include:\u003cbr\u003eIntegrated Keypad with Display.\u003cbr\u003eInternal bypass.\u003cbr\u003e2 x Digital Inputs,1 x Run Relay, 1 x Fault Relay. \u003cbr\u003eUSB terminal for firmware upgrades and data logging.\u003cbr\u003eRJ45 Socket for Modbus RTU communications.\u003c\/p\u003e\n\u003cp\u003eInput Voltage: 200Vac to 600Vac, at 50\/60Hz +\/- 10%\u003cbr\u003eSupply fuse rating 250A, semiconductor type aR - see linked products below.\u003cbr\u003eRequires external power supply (not included, see linked products below) or compatible 24V 2A DC supply for operation.\u003c\/p\u003e\n\u003cp\u003eCubicle mount.\u003cbr\u003eVentilation space above and below: 75mm\u003cbr\u003eVentilation space at sides: 25mm (each side)\u003cbr\u003eVentilation space in front: 25mm\u003cbr\u003eMounting via 4 bolts at rear on 165mm x 90mm centres.\u003cbr\u003eOperating Temp: -20°C to 40°C. Above 40°C derate linearly by 2% per °C to a maximum of 60°C\u003cbr\u003eHeat loss: 30W.\u003c\/p\u003e\n\u003cp\u003eManufacturer part number is VMX-AGY-113-6-01. Identical to previous part AGY-113-6-01 except for branding (Fairford became Mototronics UK in 2019).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eDownload the Motortronics Agility Manuals from the links below:-\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul class=\"linkedfiles\"\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-015-Manual.pdf?v=1774223072\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-Quick-Start-Guide.pdf?v=1774223032\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Quick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-Soft-Starter-Trip-Class-Guide.pdf?v=1769575444\" rel=\"noopener\" target=\"_blank\"\u003eSoft Starter Trip Class Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060499742801,"sku":"AGY-113-6-01","price":2242.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Motortronics_AGY.jpg?v=1777721840"},{"product_id":"agility-soft-starter-45kw-80a-tc10-200-600vac","title":"AGILITY Soft Starter - 45kW, 80A TC10 200-600Vac","description":"\u003cp itemprop=\"description\"\u003eMotortronics Agility Series Soft Starter suitable for starting standard three phase induction motors to 45kW (75HP) at 80A subject to application.\u003c\/p\u003e\n\u003cp\u003eRated to suit motors and Trip Class Ratings:-\u003cbr\u003e45kW, 80A at 400V - Trip Class 10.\u003cbr\u003e37kW, 66A at 400V - Trip Class 20.\u003cbr\u003e30kW, 55A at 400V - Trip Class 30. See trip class guide below.\u003c\/p\u003e\n\u003cp\u003eUp to 5 starts per hour as standard, Up to 40 starts per hour if optional fan is fitted - see linked products for details.\u003c\/p\u003e\n\u003cp\u003eMain Circuit IP00 (IP20 with optional finger guard, see linked products below). Control Circuit IP20.\u003c\/p\u003e\n\u003cp\u003eFrame 2 Dimensions: 296mm high x147mm wide x 237mm deep. \u003cbr\u003eWeight: 6kg.\u003c\/p\u003e\n\u003cp\u003eFeatures include:\u003cbr\u003eIntegral OLED Display for fast programming.\u003cbr\u003eInternal bypass.\u003cbr\u003e2 x Digital Inputs, 1 x Run Relay, 1 x Fault Relay. \u003cbr\u003eUSB terminal for firmware upgrades and data logging..\u003cbr\u003eModbus RTU Fieldbus communications port built in.\u003c\/p\u003e\n\u003cp\u003eInput Voltage: 200Vac to 600Vac, at 50\/60Hz +\/- 10%\u003cbr\u003eSupply fuse rating: 400A semiconductor fuse type aR - see linked products below.\u003cbr\u003eRequires external power supply (not included, see linked products below) or compatible 24V 2A DC supply for operation.\u003c\/p\u003e\n\u003cp\u003eCubicle mount.\u003cbr\u003eVentilation space above and below: 100mm\u003cbr\u003eVentilation space at sides: 40mm\u003cbr\u003eVentilation space in front: 25mm\u003cbr\u003eMounting via 4 bolts at rear on 283mm x 75mm centres.\u003cbr\u003eOperating Temp: -20°C to 40°C. Above 40°C derate linearly by 2% per °C to a maximum of 60°C\u003cbr\u003eHeat loss: 37W.\u003c\/p\u003e\n\u003cp\u003eManufacturer part number is VMX-AGY-201-6-01. Identical to previous part AGY-201-6-01 except for branding (Fairford became Motortronics UK in 2019).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eDownload the Motortronics Agility Manuals from the links below:-\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul class=\"linkedfiles\"\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-015-Manual.pdf?v=1774223072\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-Quick-Start-Guide.pdf?v=1774223032\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Quick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-Soft-Starter-Trip-Class-Guide.pdf?v=1769575444\" rel=\"noopener\" target=\"_blank\"\u003eSoft Starter Trip Class Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060499775569,"sku":"AGY-201-6-01","price":3603.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Motortronics_AGY.jpg?v=1777721840"},{"product_id":"agility-soft-starter-55kw-106a-tc10-200-600vac","title":"AGILITY Soft Starter - 55kW, 106A TC10 200-600Vac","description":"\u003cp itemprop=\"description\"\u003eMotortronics Agility Series Soft Starter suitable for starting standard three phase induction motors to 55kW (75HP) at 106A subject to application.\u003c\/p\u003e\n\u003cp\u003eRated to suit motors and Trip Class Ratings:-\u003cbr\u003e55kW, 106A at 400V - Trip Class 10.\u003cbr\u003e45kW, 80A at 400V - Trip Class 20.\u003cbr\u003e37kW, 66A at 400V - Trip Class 30. See trip class below.\u003cbr\u003eCan alos be used on 230V 3 phase and 500V supplies, see mnaual for details.\u003c\/p\u003e\n\u003cp\u003eUp to 5 starts per hour as standard, Up to 40 starts per hour if optional fan is fitted - see linked products for details.\u003c\/p\u003e\n\u003cp\u003eMain Circuit IP00 (IP20 with optional finger guard, see linked products below). Control Circuit IP20.\u003c\/p\u003e\n\u003cp\u003eFrame 2 Dimesnsions: 296mm high x 147mm wide x 237mm deep. \u003cbr\u003eWeight: 6kg.\u003c\/p\u003e\n\u003cp\u003eFeatures include:\u003cbr\u003eIntegral OLED Display for fast programming.\u003cbr\u003eInternal bypass.\u003cbr\u003e2 x Digital Inputs,1 x Run Relay, 1 x Fault Relay. \u003cbr\u003eUSB terminal for firmware upgrades and data logging..\u003cbr\u003eModbus RTU Fieldbus communications port built in.\u003c\/p\u003e\n\u003cp\u003eInput Voltage: 200Vac to 600Vac, at 50\/60Hz +\/- 10%\u003cbr\u003eSupply fuse rating: 400A, semiconductor type aR - see linked products below.\u003cbr\u003eRequires external power supply (not included, see linked products below) or compatible 24V 2A DC supply for operation.\u003c\/p\u003e\n\u003cp\u003eCubicle mount.\u003cbr\u003eVentilation space above and below: 100mm\u003cbr\u003eVentilation space at sides: 40mm\u003cbr\u003eVentilation space in front: 25mm\u003cbr\u003eMounting via 4 bolts at rear on 165mm x 90mm centres.\u003cbr\u003eOperating Temp: -20°C to 40°C. Above 40°C derate linearly by 2% per °C to a maximum of 60°C\u003cbr\u003eHeat loss: 49W.\u003c\/p\u003e\n\u003cp\u003eManufacturer part number is VMX-AGY-203-6-01 . Identical to previous part AGY-203-6-01 except for branding (Fairford became Mototrtronics UK in 2019).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eDownload the Motortronics Agility Manuals from the links below:-\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul class=\"linkedfiles\"\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-015-Manual.pdf?v=1774223072\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-Quick-Start-Guide.pdf?v=1774223032\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Quick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-Soft-Starter-Trip-Class-Guide.pdf?v=1769575444\" rel=\"noopener\" target=\"_blank\"\u003eSoft Starter Trip Class Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060499808337,"sku":"AGY-203-6-01","price":4021.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Motortronics_AGY.jpg?v=1777721840"},{"product_id":"agility-soft-starter-75kw-132a-tc10-200-600vac","title":"AGILITY Soft Starter - 75kW, 132A TC10 200-600Vac","description":"\u003cp itemprop=\"description\"\u003eMotortronics Agility Series Soft Starter suitable for starting standard three phase induction motors to 75kW (100HP) at 132A subject to application.\u003c\/p\u003e\n\u003cp\u003eRated to suit motors and Trip Class Ratings:-\u003cbr\u003e75kW, 132A at 400V - Trip Class 10.\u003cbr\u003e55kW, 106A at 400V - Trip Class 20\u003cbr\u003e45kW, 80A at 400V - Trip Class 30. See trip class guide below.\u003cbr\u003eCan also be used on 230V 3 phase and 500V supplies, see manuals for details.\u003c\/p\u003e\n\u003cp\u003eUp to 5 starts per hour as standard, Up to 30 starts per hour if optional fan is fitted - see linked product below.\u003c\/p\u003e\n\u003cp\u003eMain Circuit IP00 (IP20 with optional finger guard, see linked products below). Control Circuit IP20.\u003c\/p\u003e\n\u003cp\u003eFrame 2 Dimensions: 296mm high x 147mm wide x 237mm deep. \u003cbr\u003eWeight: 6kg.\u003c\/p\u003e\n\u003cp\u003eFeatures include:\u003cbr\u003eIntegral OLED Display for fast programming.\u003cbr\u003eInternal  bypass.\u003cbr\u003e2 x Digital Inputs, 1 x Run Relay, 1 x Fault Relay. \u003cbr\u003eUSB terminal for firmware upgrades and data logging..\u003cbr\u003eModbus RTU Fieldbus communications port built in.\u003c\/p\u003e\n\u003cp\u003eInput Voltage: 200Vac to 600Vac, at 50\/60Hz +\/- 10%\u003cbr\u003eSupply fuse rating 550A: semiconductor type aR - see linked pproducts below.\u003cbr\u003eRequires external power supply (not included, see linked products below) or compatible 24V 2A DC supply for operation.\u003c\/p\u003e\n\u003cp\u003eCubicle mount.\u003cbr\u003eVentilation space above and below: 100mm\u003cbr\u003eVentilation space at sides: 40mm\u003cbr\u003eVentilation space in front: 25mm\u003cbr\u003eMounting via 4 bolts at rear on 283mm x 75mm centres.\u003cbr\u003eOperating Temp: -20°C to 40°C. Above 40°C derate linearly by 2% per °C to a maximum of 60°C\u003cbr\u003eHeat loss: 61W.\u003c\/p\u003e\n\u003cp\u003eManufacturer part number is VMX-AGY-205-6-01. Identical to previous part AGY-205-6-01 except for branding (Fairford became Mototronics UK in 2019).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eDownload the Motortronics Agility Manuals from the links below:-\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul class=\"linkedfiles\"\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-015-Manual.pdf?v=1774223072\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-Quick-Start-Guide.pdf?v=1774223032\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Quick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-Soft-Starter-Trip-Class-Guide.pdf?v=1769575444\" rel=\"noopener\" target=\"_blank\"\u003eSoft Starter Trip Class Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060499841105,"sku":"AGY-205-6-01","price":4266.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Motortronics_AGY.jpg?v=1777721840"},{"product_id":"agility-soft-starter-90kw-160a-tc10-200-600vac","title":"AGILITY Soft Starter 90kW, 160A TC10 200-600Vac","description":"\u003cp itemprop=\"description\"\u003eMotortronics Agility Series Soft Starter suitable for starting standard three phase induction motors to 90kW (120HP) at 160A subject to application.\u003c\/p\u003e\n\u003cp\u003eRated to suit motors and Trip Class Ratings:-\u003cbr\u003e90kW, 160A at 400V - Trip Class 10.\u003cbr\u003e75kW, 132A at 400V - Trip Class 20.\u003cbr\u003e55kW, 106A at 400V - Trip Class 30.  See trip class guide below.\u003cbr\u003eCan be used on 230V 3 phase and 500V supplies, see manual for details.\u003c\/p\u003e\n\u003cp\u003eUp to 5 starts per hour as standard, Up to 20 starts per hour if optional fan is fitted - see linked products below.\u003c\/p\u003e\n\u003cp\u003eMain Circuit IP00 (IP20 with optional finger guard, see linked products below). Control Circuit IP20.\u003c\/p\u003e\n\u003cp\u003eFrame 2 Dimensions: 296mm high x 147mm wide x 237mm deep. \u003cbr\u003eWeight: 6kg.\u003c\/p\u003e\n\u003cp\u003eFeatures include:\u003cbr\u003eIntegral OLED Display for fast programming.\u003cbr\u003eInternal bypass.\u003cbr\u003e2 x Digital Inputs, 1 x Run Relay, 1 x Fault Relay. \u003cbr\u003eUSB terminal for firmware upgrades and data logging..\u003cbr\u003eModbus RTU Fieldbus communications port built in.\u003c\/p\u003e\n\u003cp\u003eInput Voltage: 200Vac to 600Vac, at 50\/60Hz +\/- 10%\u003cbr\u003eSupply fuse rating: 550A semiconductor type aR- see linked products below.\u003cbr\u003eRequires external power supply (not included, see linked products below) or compatible 24V 2A DC supply for operation..\u003c\/p\u003e\n\u003cp\u003eCubicle mount.\u003cbr\u003eVentilation space above and below: 100mm\u003cbr\u003eVentilation space at sides: 40mm\u003cbr\u003eVentilation space in front: 25mm\u003cbr\u003eMounting via 4 bolts at rear on 283mm x 75mm centres.\u003cbr\u003eOperating Temp: -20°C to 40°C. Above 40°C derate linearly by 2% per °C to a maximum of 60°C\u003cbr\u003eHeat loss: 74W.\u003c\/p\u003e\n\u003cp\u003eManufacturer part number is VMX-AGY-207-6-01. Identical to previous part AGY-207-6-01 except for branding (Fairford became Motortronics UK in 2019).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eDownload the Motortronics Agility Manuals from the links below:-\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul class=\"linkedfiles\"\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-015-Manual.pdf?v=1774223072\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-Quick-Start-Guide.pdf?v=1774223032\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Quick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-Soft-Starter-Trip-Class-Guide.pdf?v=1769575444\" rel=\"noopener\" target=\"_blank\"\u003eSoft Starter Trip Class Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060499939409,"sku":"AGY-207-6-01","price":4619.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Motortronics_AGY.jpg?v=1777721840"},{"product_id":"agility-soft-starter-110kw-195a-tc10-200-600vac","title":"AGILITY Soft Starter 110kW, 195A TC10 200-600Vac","description":"\u003cp itemprop=\"description\"\u003eMotortronics Agility Series Soft Starter suitable for starting standard three phase induction motors to 110kW (132HP) at 195A subject to application.\u003c\/p\u003e\n\u003cp\u003eRated to suit motors and Trip Class Ratings:-\u003cbr\u003e110kW, 195A at 400V - Trip Class 10.\u003cbr\u003e90kW, 160A at 400V - Trip Class 20. \u003cbr\u003e75kW, 132A at 400V - Trip Class 30. See trip class guide below.\u003cbr\u003eCan also be used on 230V 3 phase and 500V supplies, see manual for details.\u003c\/p\u003e\n\u003cp\u003eUp to 5 starts per hour as standard, Up to 10 starts per hour if optional fan is fitted - see linked products below.\u003c\/p\u003e\n\u003cp\u003eMain Circuit IP00 (IP20 with optional finger guard). Control Circuit IP20.\u003c\/p\u003e\n\u003cp\u003eFrame 2 Dimesnsions: 296mm high x 147mm wide x 237mm deep. \u003cbr\u003eWeight: 6kg.\u003c\/p\u003e\n\u003cp\u003eFeatures include:\u003cbr\u003eIntegral OLED Display for fast programming.\u003cbr\u003eInternal bypass.\u003cbr\u003e2 x Digital Inputs (24Vdc or 110Vac or 230Vac +\/-10% voltage dependent voltage applied to D1-2 Com terminals)\u003cbr\u003e1 x Run Relay, 1 x Fault Relay. \u003cbr\u003eUSB terminal for firmware upgrades and data logging.\u003cbr\u003eModbus RTU Fieldbus communications port built in.\u003c\/p\u003e\n\u003cp\u003eInput Voltage: 200Vac to 600Vac, at 50\/60Hz +\/- 10%\u003cbr\u003eSupply fuse rating: 550A semiconductor type aR - see linked products below.\u003cbr\u003eRequires external power supply (not included, see linked products below) or compatible 24V 2A DC supply for operation.\u003c\/p\u003e\n\u003cp\u003eCubicle mount.\u003cbr\u003eVentilation space above and below: 100mm\u003cbr\u003eVentilation space at sides: 40mm\u003cbr\u003eVentilation space in front: 25mm\u003cbr\u003eMounting via 4 bolts at rear on 283mm x 75mm centres.\u003cbr\u003eOperating Temp: -20°C to 40°C. Above 40°C derate linearly by 2% per °C to a maximum of 60°C\u003cbr\u003eHeat loss: 90W.\u003c\/p\u003e\n\u003cp\u003eManufacturer part number is VMX-AGY-209-6-01. Identical to previous part AGY-209-6-01 except for branding ( Faiford became Motorotronics UK in 2019).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eDownload the Motortronics Agility Manuals from the links below:-\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul class=\"linkedfiles\"\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-015-Manual.pdf?v=1774223072\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-Quick-Start-Guide.pdf?v=1774223032\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Quick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-Soft-Starter-Trip-Class-Guide.pdf?v=1769575444\" rel=\"noopener\" target=\"_blank\"\u003eSoft Starter Trip Class Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060500004945,"sku":"AGY-209-6-01","price":4948.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Motortronics_AGY.jpg?v=1777721840"},{"product_id":"agility-soft-starter-160kw-302a-tc10-200-600vac","title":"AGILITY Soft Starter 160kW, 302A TC10 200-600Vac","description":"\u003cp itemprop=\"description\"\u003eMotortronics Agility Series Soft Starter suitable for starting standard three phase induction motors to 132kW (200HP) at 242A subject to application.\u003c\/p\u003e\n\u003cp\u003eRated to suit motors and Trip Class Ratings:-\u003cbr\u003e160kW, 302A at 400V - Trip Class 10.\u003cbr\u003e132kW, 242A at 400V - Trip Class 20.\u003cbr\u003e110kW, 195A at 400V - Trip Class 30. See trip class guide below.\u003cbr\u003eCan also be used on 230V 3 phase and 500V supplies, see manual below.\u003c\/p\u003e\n\u003cp\u003eThe Agility frame 3 soft starters have an integral fan.\u003c\/p\u003e\n\u003cp\u003eMain Circuit IP00 (IP20 with optional finger guard). Control Circuit IP20.\u003c\/p\u003e\n\u003cp\u003eFrame 3 Dimesnsions: 490mm high x 205mm wide x 332mm deep. \u003cbr\u003eWeight: 15kg.\u003c\/p\u003e\n\u003cp\u003eFeatures include:\u003cbr\u003eIntegral OLED Display for fast programming.\u003cbr\u003eInternal bypass.\u003cbr\u003e2 x Digital Inputs (24Vdc or 110Vac or 230Vac +\/-10% voltage dependent voltage applied to D1-2 Com terminals)\u003cbr\u003e1 x Run Relay, 1 x Fault Relay. \u003cbr\u003eUSB terminal for firmware upgrades and data logging..\u003cbr\u003eModbus RTU Fieldbus communications port built in.\u003c\/p\u003e\n\u003cp\u003eInput Voltage: 200Vac to 600Vac, at 50\/60Hz +\/- 10%\u003cbr\u003eSupply fuse rating 900A semiconductor type aR - see linked products below.\u003cbr\u003eRequires external power supply (not included, see linked products below) or compatible 24V 2A DC supply for operation.\u003c\/p\u003e\n\u003cp\u003eCubicle mount.\u003cbr\u003eVentilation space above and below: 100mm\u003cbr\u003eVentilation space at sides: 40mm\u003cbr\u003eVentilation space in front: 25mm\u003cbr\u003eMounting via 4 bolts at rear on 283mm x 75mm centres.\u003cbr\u003eOperating Temp: -20°C to 40°C. Above 40°C derate linearly by 2% per °C to a maximum of 60°C\u003cbr\u003eHeat loss: 139W.\u003c\/p\u003e\n\u003cp\u003eManufacturer part number is VMX-AGY-303-6-01. Identical to previous part AGY-303-6-01 except for branding (Fairford became Motortronics UK in 2019).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eDownload the Motortronics Agility Manuals from the links below:-\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul class=\"linkedfiles\"\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-015-Manual.pdf?v=1774223072\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-Quick-Start-Guide.pdf?v=1774223032\" rel=\"noopener\" target=\"_blank\"\u003eVMX AGY Agility Quick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-Soft-Starter-Trip-Class-Guide.pdf?v=1769575444\" rel=\"noopener\" target=\"_blank\"\u003eSoft Starter Trip Class Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060500037713,"sku":"AGY-303-6-01","price":6058.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Motortronics_AGY.jpg?v=1777721840"},{"product_id":"agility-soft-starter-200kw-361a-tc10-200-600vac","title":"AGILITY Soft Starter 200kW, 361A TC10 200-600Vac","description":"\u003cp itemprop=\"description\"\u003eMotortronics Agility Series Soft Starter suitable for starting standard three phase induction motors to 200kW (200HP) at 361A subject to application.\u003c\/p\u003e\n\u003cp\u003eRated to suit motors and Trip Class Ratings:-\u003cbr\u003e200kW, 361A at 400V - Trip Class 10.\u003cbr\u003e160kW, 302A at 400V - Trip Class 20.\u003cbr\u003e132kW, 242A at 400V - Trip Class 30. See trip class guide below.\u003c\/p\u003e\n\u003cp\u003eThe Agility frame 3 soft starters have an integral fan.\u003c\/p\u003e\n\u003cp\u003eMain Circuit IP00 (IP20 with optional finger guard). Control Circuit IP20.\u003c\/p\u003e\n\u003cp\u003eFrame 3 Dimesnsions: 490mm high x 205mm wide x 332mm deep. \u003cbr\u003eWeight: 15kg.\u003c\/p\u003e\n\u003cp\u003eFeatures include:\u003cbr\u003eIntegral OLED Display for fast programming.\u003cbr\u003eInternal bypass.\u003cbr\u003e2 x Digital Inputs, 1 x Run Relay, 1 x Fault Relay. \u003cbr\u003eUSB terminal for firmware upgrades and data logging..\u003cbr\u003eModbus RTU Fieldbus communications port built in.\u003c\/p\u003e\n\u003cp\u003eInput Voltage: 200Vac to 600Vac, at 50\/60Hz +\/- 10%\u003cbr\u003eSupply fuse rating: 1000A semiconductor aR type - see linked products below.\u003cbr\u003eRequires external power supply (not included, see linked products below) or compatible 48VA, 24V (2A) DC supply for operation.\u003c\/p\u003e\n\u003cp\u003eCubicle mount.\u003cbr\u003eVentilation space above and below: 100mm\u003cbr\u003eVentilation space at sides: 40mm\u003cbr\u003eVentilation space in front: 25mm\u003cbr\u003eMounting via 4 bolts at rear on 283mm x 75mm centres.\u003cbr\u003eOperating Temp: -20°C to 40°C. Above 40°C derate linearly by 2% per °C to a maximum of 60°C\u003cbr\u003eHeat loss: 166W.\u003c\/p\u003e\n\u003cp\u003eManufacturer part number is VMX-AGY-305-6-01. Identical to previous part AGY-305-6-01 except for branding (Fairford became Motortronics UK in 2019).\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eDownload the Motortronics Agility Manuals from the links below:-\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul class=\"linkedfiles\"\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-015-Manual.pdf?v=1774223072\" target=\"_blank\" rel=\"noopener\"\u003eVMX AGY Agility Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-VMX-AGY-Quick-Start-Guide.pdf?v=1774223032\" target=\"_blank\" rel=\"noopener\"\u003eVMX AGY Agility Quick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"linkedfiles_pdf\"\u003e\u003ca href=\"https:\/\/invertek.au\/cdn\/shop\/files\/Motortronics-Soft-Starter-Trip-Class-Guide.pdf?v=1769575444\" target=\"_blank\" rel=\"noopener\"\u003eSoft Starter Trip Class Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MOTORTRONICS","offers":[{"title":"Default Title","offer_id":59060500070481,"sku":"AGY-305-6-01","price":6737.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/files\/Motortronics_AGY.jpg?v=1777721840"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/5282\/0305\/collections\/Motortronics_AGY.jpg?v=1770350949","url":"https:\/\/www.idadrives.com\/collections\/agility.oembed","provider":"IDA","version":"1.0","type":"link"}